NRD108031 TRVC070999000 BOTTOM

Equipped with automatic testing function,
Can test performance such as bit error rate;
Equipped with status monitoring function;
Equipped with interference signal generation function;
Equipped with code table equipment
Measurement and control addition solution
Interface of confidential equipment;

Category:
Get a quote, please contact me immediately:
Simon Zhang
dcsplcsales@gmail.com
Phone/Whatsapp/Skype/Wechat: +86 133 6590 9307

Description

NRD108031 TRVC070999000 BOTTOM

NRD108031 TRVC070999000 BOTTOM

The following components should be replaced regularly: 1. The power module of the cooling fan frequency converter is the most severely heated component, and the heat generated by its continuous operation must be discharged in a timely manner. Generally, the lifespan of the fan is approximately 10Kh-40Kh. According to the conversion of continuous operation of the frequency converter, the fan needs to be replaced every 2-3 years. There are two or three lines for direct cooling fans. One line of the two line fan is the positive pole, and the other line is the negative pole. When replacing, do not connect it incorrectly; In addition to the positive and negative poles, there is also a detection wire for the three wire fan. Be careful when replacing it, otherwise it may cause the frequency converter to overheat and alarm. AC fans are generally divided into 220V and 380V, and the voltage level should not be mistaken when replacing them. 2. Filter capacitor: Intermediate circuit filter capacitor: also known as electrolytic capacitor, its main function is to smooth DC voltage and absorb low-frequency harmonics in DC. The heat generated by its continuous operation and the heat generated by the frequency converter itself will accelerate the drying of its electrolyte, directly affecting its capacity. Under normal circumstances, the service life of the capacitor is 5 years. It is recommended to regularly check the capacity of the capacitor once a year. Generally, if the capacity is reduced by more than 20%, it should be replaced. Conclusion: To ensure the safe and stable operation of your equipment, please spend more time and effort on maintaining your frequency converter. Abstract: How the working condition of the frequency converter directly affects the operation of the equipment? To ensure the normal operation of the frequency converter, this article introduces the maintenance methods of the frequency converter to everyone. Keywords: frequency converter electrolytic capacitor Reference: Design and maintenance of frequency converter speed control system

MHD115B-058-NP0-BN
MHD115C-058-NP1-BN
MHD115C-058-PP0-BN
MHD115C-024-NP1-BN
MHD115B-024-NP0-AA
MHD115A-024-NP0-AA
MHD115C-024-NP0-AN
MHD115C-024-PG0-BA
MHD115C-024-NG1-BA
MHD115C-058-NG1-BN
MHD115C-024-NG1-AA
MHD115B-024-NG1-AA
MHD115A-024-PG0-BA
MHD115C-024-PG1-AA
MHD115C-024-NP0-AA
MHD115B-024-PG1-BA
MHD115B-024-PG0-AA