Description
IOP320 Internal Register
IOP320 is mainly in the parameter setting aspect, here mainly introduces the position parameter setting of the axis, the most important part in this system is the servo system, which is the core to ensure the accuracy of the system, the parameter and data setting of the servo system is very complex, Figure 6 is the basic framework structure diagram of the servo system parameter setting, the basic parameters are mainly unit setting, 1 pulse of the considerable amount of movement, pulse output mode, The basic parameters are unit setting, equivalent movement of 1 pulse, pulse output mode, direction of rotation, speed limit value, acceleration and deceleration time, and motor selection.
IOP320 on the above description of some of the detailed settings, but also for other functions, such as M-code take code mode, speed mode, JOG operation, manual pulse selection, arc error correction and so on. The home reset parameter settings are mainly the way of resumption, direction, home address, and speed. Positioning data is how we ask the system to work, work steps, data and other content.
IOP320 servo system works mainly on the internal register address operation, mainly divided into the parameter area, monitoring area, system control data area, positioning data area, PLC’s CPU memory area, the block transfer area of several parts. IOP320 settings for each position (QD75) is mainly the setup of the basic positioning data, including the positioning identifier, the M code, the command speed, the positioning address / Move amount, sudden stop deceleration time, arc address, of which a total of 30 points of position per axis is set, so that it can effectively adapt to the system cutting complexity of different substrates.