Description
ABB Unigear with double busbar system Breaker AIS ABB MV Products
ABB Unigear with double busbar system Breaker AIS ABB MV Products
Unigear with double busbar : Medium voltage, arc-proof, air-insulated switchgear
UniGear-ABB’s medium voltage air-insulated switchgear, is the result of ABB’s global know-how integrated into a single technological solution and is also ABB’s answer to the range of solutions demanded by global markets. The switchgear complies with IEC 62271-200 standards. ‘Made in ABB’, UniGear comes with the same design and quality standards across 5 continents, and offers the best solutions for all installations including power plants, power distribution substations, compact Motor Control Centers, double-level, duplex and special-unit switchgear.
SALIENT FEATURES
- Metal-clad, four-sided internal arc-proof construction (IAC AFLR)
- Designed in conformance with the highest in class for minimum Loss of Service Continuity – ‘LSC-2B with metallic partitions’
- Constructed with pre-galvanized sheets without welding points, making it the most reliable switchgear in its range
- REF542 and other high-end communicable relays offer intelligent solutions for all installation requirements
- It is virtually maintenance-free and all circuitbreaker operations can be carried out with the door closed
- Earthing-switch is provided as an option. It is rated for full making capacity and is provided with safe and reliable position indicators
- All compartments can be accessed from the front, hence the switchgear can be placed against the wall
- The switchgear is provided with conventional or integrated protection and measurement systems
- It is fitted with conventional instrument transformers or new generation sensors
Apparatus which can be installed in UniGear Switchgear
VACUUM CIRCUIT-BREAKER – CASSETTE VERSION
- Circuit-breaker for all fields of application
- Vacuum Interrupters, using radial magnetic field contact system, rotate arc column over the complete contact periphery to give the best current-interruption performance at all current values
- Epoxy resin poles for greater protection of the interrupters
VACUUM CIRCUIT-BREAKER – FLOOR-ROLLING VERSION
- Circuit-breaker for all fields of application
- Vacuum Interrupters, using radial magnetic field contact system, rotate arc column over the complete contact periphery to give the best current-interruption performance at all current values
- Epoxy resin poles for greater protection of the interrupters
VACUUM CIRCUIT-BREAKER WITH MAGNETIC DRIVE
- The magnetic actuator is a bi-stable system with electromagnetic coils for driving the armature and permanent magnet for latching on to the end positions
- All functions like charging, switching, controlling and self-diagnostics are carried out from an integrated electronic controller
- Equipped with multi voltage feeder in direct and alternating current
VACUUM CONTACTORS
- Optimal solution for motor and transformer switching and switching of capacitor bank for power-factor control
- Fitted with medium voltage fuses according to DIN and BS Standards
- Availability of operating mechanisms with electric or mechanical latching functions
- Equipped with multi voltage feeder in direct and alternating current
Each switchboard consists of a single switchgear, which can be equipped with a circuit-breaker or contactor along with all accessories required for the switchgear. Each switchgear is provided with a metering compartment, placed in the upper part, for auxiliary instrumentation. The units can be coupled together with either ZVC or Double- level units, with the possibility of extension on both ends of the switchgear. The switchgear can be accessed from both, front and rear sides for installation and maintenance purposes. All the service operations are carried out from the front.
UniGear with double busbar system
The double busbar system switchgear is based on two different schemes:
- two bus bar systems, two line-side isolators and a circuit-breaker (actual system)
- two bus bar systems, two circuit-breaker units with one or two circuit-breakers (duplex system).
The schemes offer redundancy of the bus bar system with physical isolation between the systems. The use of this switchgear may be necessary in the case of:
- switch incoming units with unsynchronized circuit breakers – disconnection of loads with different levels of importance under emergency conditions
- Isolation of particular outgoing units from the normal network
- balance of the outgoing units under normal service conditions
- flexibility during the inspection and maintenance procedures without interruption of the load
- possibility of extension without turning the
- Switchgear off.
The switchgear offers:
- Line with double isolation up to 2500 A
- 3150 A and 4000 A duplex line
- Segregated busbar and isolation compartments
- Earthing switch with making capacity
- Operations can be carried out from the front
- Reliable and uninterrupted service conditions