Description
8V1180.00-2ACOPOS Vacuum Pump Solenoid Valve
8V1180.00-2ACOPOS In order to prevent crashing, the left table can only be started when the right limit of the right table is pressed down; similarly, the right table can only be started when the left limit of the left table is pressed down. When the manual/automatic transfer switch selects manual, the feeding, pre-pressing, forming, pressure relief and discharging processes are controlled by the corresponding buttons; when the manual/automatic transfer switch selects automatic, the whole process from feeding to discharging can be completed automatically by pressing the left or right working table start button.
When 8V1180.00-2ACOPOS left working table is allowed to start, press the left working table start button, the motor will positively rotate to feed the material into the working box, and then it will be heated for a certain period of time set by TIM000, the solenoid valve of the vacuum pump will be opened to carry out a short period of pre-pressurization (about three seconds set by TIM001), and then it will be shaped (set by TIM002), and then it will be delayed for a certain period of time (set by TIM003), and finally the product will be sent out. then forming (set by TIM002), delaying for a certain time (set by TIM003), and finally sending the product out until the left limit of the left working table is pressed down, the whole working process is finished.