Description
GE IS200VCMIH2CAA module
GE IS200VCMIH2CAA module
A typical communication failure phenomenon is that all irregular communication on the OVATION side becomes bad points and cannot self heal. Only by restarting a pair of controllers can the failure phenomenon be eliminated. At first, we believed that the OVATION controller CPU was overloaded due to excessive communication points and dense sampling frequency; We have tried to reduce communication points, reduce refresh frequency, refresh the SDB database of the GE CRM operation station, and even allocate communication tasks to two different controller groups, but the fault phenomenon still exists. After repeated experiments, it was found that in addition to physical link interruption (such as unplugging the network cable), there is another situation that can cause the VATION controller to lose response to communication: when the CRM operation station on the MARK VI side performs a REBUILD operation. From the existing data of GE, it is known that the REBUILD of each operation station and engineer station is actually the compilation process of HMB. That is, the engineer changes the M6B configuration file of the MARK VI controller, such as adding EGD points. After the configuration software is compiled, an HMB file is generated, and an independent HMB is distributed for each HMI. The user compiles the HMB file through the REBUILD operation and passes the configuration information to the CIMPLICITY and TCI (turbine control interface) of each HMI station. Thus, new EGD points can be obtained in the CIMPLICITY process screen. So, when the M6B file of the MARK VI controller changes, each HMI station must perform a REBUILD operation. It is worth noting that during the REBUILD process of each CRM station, the system will stop and restart the city and TCI, during which a vacuum period of GSM data packets will be generated. It is also at this time that the OVATION controller encounters a communication failure and refuses to refresh the communication point. It is not difficult to understand why the REBUILD operation produces the same fault phenomenon as link interruption. We know from the relevant Westinghouse documents that the OVATION controller is embedded with a VxWorks operating system similar to U-NIX. The operating system kernel supports TCP/IP protocol, so it can take on the task of receiving GE GSM data packets.
TP854 3BSE025349R1
KUC720AE01
3BHB003431R0001
3BHB000652R0001
3BSE025349R1
3BSE030220R1 CI854A
3BSE030220R1
TVOC-2-240 1SFA664001R1001
TVOC-2-240
1SFA664001R1001
AX722F 3BDH000377R0001
AX722F
3BDH000377R0001
SDCS-AMC-CLAS2
GJR5252300R3101 07AC91H
07AC91H
TB711F 3BDH000365R0001
TB711F
3BDH000365R0001
PM783F 3BDH000364R0001
3BDH000364R0001
CM772F 3BDH000368R0001
CM772F
3BDH000368R0001
PFTL101A-2.0KN 3BSE004172R1
PFTL101A-2.0KN
TU715F 3BDH000378R0001
TU715F
3BDH000378R0001
DC732F 3BDH000375R0001
DC732F
3BDH000375R0001
TTH300
UNS3670A-Z V2 HIEE205011R0002
UNS3670A-Z V2
RC527 3BSE008154R1
RC527
3BSE008154R1
5SHY5055L0002
3BHE019719R0101
CI532V05 3BSE007297R1
CI532V05
3BSE007297R1
REF615CE HCFDACADABC2BAN11E
REF615CE
HCFDACADABC2BAN11E
TK803V018 3BSC950130R1
TK803V018
3BSC950130R1
REF615EE HBFHAEAGNCA1BNN1XE
REF615EE
HBFHAEAGNCA1BNN1XE
TP830 3BSE018114R1
UNITROL 1020
UNS0119A-ZV1
3BHE030579R0003
DSAI146 3BSE007949R1
DSAI146
3BSE007949R1
LC-608
RF522 3BSE000743R1
RF522
3BSE000743R1