Description
IC693DNM200 Inverter Modules
The IC693DNM200 uses a high-speed counter for multi-point positioning, mainly for precise positioning. Positioning accuracy is determined both by the measurement of the high-speed counter and the execution speed of the actuator.
IC693DNM200 If a normal output instruction is used, during the program execution phase of a scan cycle, what is changed is only the output image memory, and the output points of the PLC will not be refreshed immediately, and only after the program execution is completed, the output image memory of the PLC will be refreshed for the output points and the output will be executed.
IC693DNM200 In order to increase positioning accuracy, immediate output instructions are used as much as possible. The immediate output instruction is not limited by the PLC scan cycle phase and immediately refreshes the PLC output points while changing the output image memory.