Description
PPD113B01-10-150000 Digital Output Board
PPD113B01-10-150000The PPD113B01-10-150000 is able to input logic to the emergency button; this way, if the motor is accidentally still on, it can be stopped immediately by pressing it. Therefore, jogging is a very important feature in motor applications.
The motors used are very heavy rated. Such motors attract a lot of starting current. It is a different case that starters are used for them, such as star-delta, Vfd, or soft starters. But, in fact, despite the use of starters, it must be observed that these motors consume a large amount of current during starting.
Moreover, when they are stopped, the sudden stop causes a heavy load on the connected output. Therefore, it is recommended to perform only 5-6 jogging operations. After that, it must run normally or stop for a certain period of time.
Frequent jogging can cause a heavy load on the motor windings or overheating can damage them. With all these factors in mind, there are several important considerations to take into account when jogging.
When to use:
Increase in motor size and horsepower rating to support strong inrush currents.
Properly designed logic or circuits (must use momentary logic, not switching logic.)
A converter can be used to reduce the voltage to the motor during scaling, or a reactor or resistor can be connected in series with the motor to reduce the current supplied to the power line.
Always check standard automotive ratings like current, torque, horsepower, and voltage before jogging operation. If the ratings are low, then they must be increased to support the jogging.
How to operate PPD113B01-10-150000:
This is done according to the duty cycle of the motor. The duty cycle of the motor specifies the recommended number of starts/minutes or starts/hours. Excessive starting leads to overheating of the motor and ultimately to insulation failure of the motor.The S4 motor is suitable for jogging and flushing operations.
When using the VFD for jogging, enter appropriate parameters such as jogging frequency, jogging maximum run time, jogging acceleration and deceleration time. The VFD provides the best control for participating in jogging training.
Product details | |||
Delivery time | Available | Estimated Lead Time | 3-5 weeks |
Factory warraty | 12 months | Module number | PPD113B01-10-150000 |
Manufacturer | original country | Product Name | controller/plc/dcs/servo/panel |
Voltage range (VDC) | 24-120vdc | Output range (mA) | 120 |
Over-range protection (VDC) | 21dd. | Input range (mA) | 33 |
Working temperature | 240 | System memory (Mb | 125 |
Interface | 6 | Color code | WHITE、GREY、BLACK |
Weight (KG) | 0.32 | Shipping weight (KG) | 1.25 |
Dimension (mm*mm*mm) | 324*234*22.5 | Purpose | Petrochemical industries |
Operation mode | Direct on-board | Product situation | Stop production |